DC/DC Converter
THR 40WI Series, 40 Watt
•
•
Reinforced I/O-isolation 3000 VAC
•
Wide 4:1 input voltage range: 36-160
VDC
•
Operating temperature range -40 to
+80°C
•
•
•
Shock and vibration resistance
according to EN 61373
UL 62368-1 IEC 62368-1
High efficiency up to 90%
The THR 40WI is 40 Watt DC/DC converters series with reinforced isolation
(3000 VAC). These regulated DC/DC converters come in either a 2"x1" packProtection against overload, overvoltage
age and also feature increased resistance against shock and vibration accordand short circuit
ing to EN 61373. High efficiencies up to 90% allow safe operation from –40°C
to +70°C (with derating). All models have a wide 4:1 input voltage range and
3-year product warranty
precisely regulated, isolated output voltages. With the latest IT safety certifications (IEC/EN/UL 62368-1) the THR 40WI series is the perfect choice for many
demanding applications in the industrial, transportation and instrumentation
sectors.
Models
Order Code
Input Voltage
THR 40-7211WI
THR 40-7212WI
THR 40-7213WI
THR 40-7215WI
THR 40-72154WI
THR 40-7222WI
THR 40-7223WI
Output 1
Output 2
Range
Vnom
Imax
36 - 160 VDC
(110 VDC nom.)
5 VDC
12 VDC
15 VDC
24 VDC
54 VDC
+12 VDC
+15 VDC
8'000 mA
3'330 mA
2'670 mA
1'670 mA
741 mA
1'670 mA
1'330 mA
Vnom
–12 VDC
–15 VDC
Efficiency
Imax
typ.
1'670 mA
1'330 mA
88 %
89 %
89 %
89 %
90 %
89 %
89 %
Options
THR-HS1
- Optional Heat Sink with Height = 0.25": www.tracopower.com/products/thr-hs1.pdf
- Optional Heat Sink with Height = 0.5": www.tracopower.com/products/thr-hs2.pdf
on demand
(backorder with MOQ - Optional Heat Sink with Height = 1.0": www.tracopower.com/products/thr-hs3.pdf
non stocking item) - Optional models with pre-assembled heatsink
www.tracopower.com
September 20, 2023
Page 1 / 5
THR 40WI Series, 40 Watt
Input Specifications
Input Current
40 mA typ.
409 mA typ.
170 VDC max. (100 ms max.)
30 VDC min. / 33 VDC typ. / 35.5 VDC max.
2'500 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Voltage Balance
(symmetrical load)
- single output
- dual output
- single output
- dual output
Capacitive Load
- single output
- dual output
single output models:
dual output models:
single output models:
dual output models:
dual output models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
54 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
54 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
54 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Deviation
- Response Time
–15% to +5% (54 Vout model)
±10% (other models)
(single output models only)
(By external trim resistor)
www.tracopower.com/overview/thr40wi
Output power must not exceed rated power!
±1% max.
0.2% max.
0.2% max.
0.5% max.
1% max. (Output 1)
1% max. (Output 2)
2% max.
75 mVp-p typ. (w/ 1 µF, 100 V MLCC)
125 mVp-p typ. (w/ 1 µF, 100 V MLCC)
125 mVp-p typ. (w/ 1 µF, 100 V MLCC)
150 mVp-p typ. (w/ 1 µF, 100 V MLCC)
250 mVp-p typ. (w/ 1 µF, 100 V MLCC)
125 / 125 mVp-p typ. (w/ 1 µF, 100 V MLCC)
125 / 125 mVp-p typ. (w/ 1 µF, 100 V MLCC)
85 mVp-p max. (w/ 1 µF, 100 V MLCC)
140 mVp-p max. (w/ 1 µF, 100 V MLCC)
140 mVp-p max. (w/ 1 µF, 100 V MLCC)
170 mVp-p max. (w/ 1 µF, 100 V MLCC)
280 mVp-p max. (w/ 1 µF, 100 V MLCC)
140 / 140 mVp-p max. (w/ 1 µF, 100 V MLCC)
140 / 140 mVp-p max. (w/ 1 µF, 100 V MLCC)
13'600 µF max.
2'400 µF max.
1'500 µF max.
600 µF max.
130 µF max.
1'200 / 1'200 µF max.
750 / 750 µF max.
Not required
±0.02 %/K max.
30 ms typ. / 100 ms max.
Continuous, Automatic recovery
110 - 185% of Iout max.
150% typ. of Iout max.
125% typ. of Vout nom.
3% typ. / 5% max. (75% to 100% Load Step)
250 µs typ. (75% to 100% Load Step)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
THR 40WI Series, 40 Watt
Safety Specifications
Safety Standards
EN 62368-1
IEC 62368-1
UL 62368-1
www.tracopower.com/overview/thr40wi
PD 2
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
External filter proposal:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
FCC Part 15 class A (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
FCC Part 15 class A (with external filter)
www.tracopower.com/overview/thr40wi
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
www.tracopower.com/overview/thr40wi
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
- Operating Temperature
Power Derating
- Case Temperature
- Storage Temperature
- High Temperature
Over Temperature
Protection Switch Off
- Protection Mode
- Measurement Point
Cooling System
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Working Voltage (rated)
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
95% max. (non condensing)
–40°C to +70°C
–40°C to +80°C (with Heat Sink)
+105°C max.
–50°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/thr40wi
115°C typ. (Automatic recovery at 100°C typ.)
Case
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2.5 mA typ.
-0.5 to 0.5 mA
4'000 m max.
220 - 310 kHz (PWM)
265 kHz typ. (PWM)
Reinforced Insulation
250 VAC
3'000 VAC
1'500 VAC
1'500 VAC
1'000 MΩ min.
1'500 pF typ.
900'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
THR 40WI Series, 40 Watt
Environment
- Vibration
- Mechanical Shock
EN 61373
EN 61373
Plastic base-plate w. metal case
Non-conductive FR4 (UL 94 V-0 rated)
Non-conductive Plastic (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2 - 4 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Lead-Free Wave Soldering
260°C / 10 s max.
51.5 g
- Case to Ambient
12 K/W typ. (without Heatsink)
10.9 K/W typ. (with Heatsink THR-HS1)
9.3 K/W typ. (with Heatsink THR-HS2)
8.9 K/W typ. (with Heatsink THR-HS3)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
fda9a647-5082-4f8d-8a9d-c1c4a64790fb
Housing Material
Base Material
Isolation Frame Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thr40wi
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
THR 40WI Series, 40 Watt
Outline Dimensions
5.08 5.1
10.16
(0.4)
3
2
Pinout
(0.2)
(0.2)
1
3.3 (0.13)
1.9
(2.00)
(1.8)
Bottom View
50.8
45.72
(0.07)
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
3
Remote On/Off
Remote On/Off
4
+Vout
+Vout
5
–Vout
Common
6
Trim
–Vout
Ø1.0
(Ø0.04)
6
5
4
10.16
10.16
2.5
(0.4)
(0.4)
(0.1)
25.40
6.0
11.0
(1.00)
(0.24)
(0.43)
Dimensions in mm (inch)
Tolerances: x.x ±0.75 (±0.03)
x.xx ±0.25 (±0.01)
Pin diameter ±0.05 (±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 5 / 5